Welded stainless steel enclosure panel with rows of knock-out holes, rubber grommets and threaded conduit entries

Knock-out Holes in Stainless Steel Enclosures: Structural Configurations, Hole Diameter Specifications, Arrangement Patterns, and Waterproofing Reinforcement Design

For outdoor stainless steel electrical distribution boxes or meter boxes, sealing forms the foundation of weather resistance, and cable entry and exit points represent the sealing chain’s weakest, most easily overlooked links. Knock-out holes serve as reserved cable passages. Their structural design, hole diameter specifications, layout, and waterproof reinforcement directly define how well the box performs under IP55–IP66 protection ratings. This article takes FN enclosure’s stainless steel enclosures as its focus and systematically explores the hardware-level design logic for knock-out holes.

Pre-drilled holes in various sizes

I. Structural Types of Knock-Out Holes

A knock-out hole is essentially a circular opening pre-punched in the enclosure wall panel and connected by a thin metal strip. FN enclosure’s stainless steel enclosures use knock-out holes by default for cable entry and exit, and their structural types can be divided into three categories:

Standard Stamped Knock-Out Hole

This is the most common design: circular holes with “bridge points” are stamped into the wall panels; when needed, a thin tab is simply knocked off with a tool to create a through-hole. The advantages of this design are its simplicity and low cost, and it maintains a fully sealed enclosure when not in use.

Removable Knock-Out Hole

For applications requiring frequent cable replacement or the provision of multiple cable entry points, some enclosures are equipped with removable metal grilles (with replaceable knock-out panels), allowing for flexible adjustments later on without having to replace the entire enclosure panel.

Pre-drilled holes with seals.

For projects with confirmed cable specifications, technicians can pre-fit waterproof cable glands or sealing plugs at knock-out holes to build an integrated “hole + seal” structure and boost sealing reliability from the source.

Regardless of the design scheme, we chamfer and deburr stamped knock-out hole edges to avoid damage to cable jackets. This detail reflects our product principle: “balance simple installation with reliable protection.”

Mind map comparing standard stamped, removable and pre-drilled knockout holes, with process, features, advantages and applications for each.

II. Pore Size Specifications

The diameter of the cable entry hole directly affects the maximum cable size that can be accommodated and is a key parameter in product selection. Although the manual does not list specific values (it states “customizable”), industry conventions and product logic generally follow the guidelines below (for reference only; specific details are subject to confirmation during customization):

Small bore: φ16–φ25 mm, suitable for thin cables such as control wires, signal wires, and lighting branch circuits; commonly used for signal collection cables in electric meter boxes.
Medium bore: φ32–φ50 mm, suitable for main circuit power cables and general-purpose power cables; the primary specification for incoming cables in distribution panels.
Large bore: φ63 mm and above, used for large-cross-section incoming cables or when multiple parallel busbar leads are required.

Hole diameter specifications follow universal industry standards. First, designers pick sizes by the outer thread diameter of matching cable glands. Notably, we favor metric sizes like M12, M16, M20, M25, M32 and M40 for most domestic and export projects. Importantly, we avoid identical sizing. Instead, we leave small clearance for assembly and keep tolerances within the sealing ring’s compensation range. For one thing, oversize holes create unsealable gaps and ruin the IP rating. For another, undersize holes demand on-site reaming, which introduces burrs and scratches and damages stainless steel’s passive film. Lastly, for heavy-current cables, we use multiple small knock-out holes. This disperses stress and reduces panel deformation.

Pore sizes of various sizes

III. Layout Methods

The arrangement of knock-out holes is by no means random; rather, it follows the three principles of “electrical safety, ease of maintenance, and controllable sealing”:

Arrange the zones according to the direction of the incoming lines.

Power input ports are typically located at the bottom of the enclosure or on the lower part of the side walls, while output ports are positioned close to the internal components to facilitate standard “top-in, bottom-out” or “bottom-in, bottom-out” cable routing, thereby reducing cable crossings and electromagnetic interference.

Left-right symmetry and spare hole design.

The layout typically employs a left-right symmetrical design to ensure even stress distribution across the enclosure and a harmonious appearance; at the same time, several spare knock-out holes are provided to allow for future circuit additions or the replacement of larger-gauge wires, demonstrating the product’s forward-thinking design.

Avoid the hinge and lock areas.

When drilling holes, avoid areas subject to stress—such as door hinges and latches—to prevent the holes from weakening the door frame. Maintain a safe distance between the holes and the installation areas of internal components to prevent cables from coming into contact with live parts, and ensure that the creepage distance and clearance comply with regulations.

Cutaway diagram of an open stainless enclosure showing knockout hole positions, diameters from 25 to 50 mm, and areas to avoid near the lock and hinge.

IV. Waterproofing and Reinforcement Design

Once a knock-out hole is punched to create a through-hole, the enclosure’s seal is compromised, making waterproof reinforcement critical. FN enclosure’s stainless steel enclosures, rated IP55–IP66, employ multiple methods to reinforce the cable entry and exit points:

Sealing component options.

The most effective method is to install a waterproof cable gland (IP68 rating) to create a radial seal at the cable entry point. Fit sealing plugs on unused knockouts to maintain the enclosure’s overall airtightness. You must match cable glands and knockout openings precisely by diameter, and choose weather-resistant, anti-aging materials to withstand UV exposure and temperature fluctuations.

The entire enclosure is sealed as a single unit.

Reinforcing the knock-out holes is not an isolated step; it works in concert with the enclosure’s multi-layer sealing gaskets, double-door structure, and anti-condensation ventilation design—even if the seal at a single entry point is slightly inadequate, the overall sealing and anti-condensation system still provides a safety net, preventing moisture from accumulating inside the enclosure.

Knock-out hole reinforcement

Tapping and edge finishing.

The edges of the cut-out holes are ground, deburred, and treated with a localized corrosion-resistant coating to prevent the exposed metal at the cut edges from corroding outdoors and to stop rust from spreading from the hole edges to the rest of the enclosure. This attention to detail helps extend the service life of the stainless steel enclosure.

Before-and-after diagram of a knock-out hole edge, covering grinding, deburring and local corrosion protection in three steps.

Optional customization and reinforcement.

For coastal environments with heavy salt fog and severe corrosion, you may customize larger knock-out holes paired with stainless steel waterproof connectors, or adopt sealed cable entry plates to further boost protective redundancy at cable entry and exit points.

Waterproof reinforcement design determines long-term outdoor performance.
First, workers polish all cut edges. They remove burrs after taking out knock-out discs.
Next, they treat exposed bare metal for local anti-corrosion.
This stops rust from spreading along the hole edge over the enclosure.
Furthermore, we equip every knock-out hole with qualified IP68 cable glands or blanking plugs.
This setup compresses sealing rings radially and keeps out water and dust.
Besides, reinforcement ribs beside high-load knock-out holes boost local rigidity.
Most importantly, designers coordinate knock-out hole sealing with other enclosure protection features.
Multi-layer door seals, double doors and anti-condensation ventilation work alongside these seals.
Finally, if one cable entry has slight sealing failure, the whole system stops moisture buildup inside the cabinet.

V. We Adapt Designs for Special Application Scenarios

First, we upgrade materials and sealing solutions for coastal salt-fog environments. We select stainless steel waterproof connectors or sealed cable entry plates for extra protection.

Besides, we reserve larger knock-out holes for heavy-current projects. Multiple small holes replace one oversized opening to spread stress.

Moreover, we simplify the structure for indoor meter boxes. These boxes do not need heavy anti-corrosion treatment, That’s why we help you keep your costs under control.

In addition, we add anti-freezing sealing compounds for low-temperature northern sites. These compounds keep sealing rings flexible under cold weather.

Furthermore, we set separate knock-out zones for explosion-prone sites. We use certified flameproof cable glands to block flame spread through cable passages.

Meanwhile, we arrange side-mounted knock-out holes for overhead installation. This layout stops rainwater from flowing directly into the cable inlet.

Lastly, we leave concentrated knock-out areas for skid-mounted integrated equipment. The grouped holes match compact wiring arrangements on equipment racks.

We punch and tap these cutouts to your drawing; see stainless steel electrical enclosures. Custom enclosure fabrication explains how cutouts, gasket seats and IP rating are set on the same drawing.

VI. Conclusion

Although knock-out holes are small, they serve as a true test of the weather resistance of outdoor stainless steel enclosures. From structural design, hole diameter specifications, and layout to waterproof reinforcement, every design element is geared toward the core objective of “facilitating wiring while ensuring a completely watertight seal.” Using 304/316L stainless steel enclosures as a foundation, FN enclosure combines the meticulous design of knock-out holes with an integrated IP55–IP66 sealing system. This ensures that cable entry and exit no longer compromise protection, providing a reliable, durable, and installation-friendly enclosure solution for outdoor power distribution and metering systems.