Choose push button enclosures around the complete controls you plan to install, including the parts behind the cover. Match the mounting holes, check usable depth, and place the cable entries before you order. The finished assembly needs enough room to tighten terminals, route wires and open the lid for maintenance.
A box described as “three-hole, 22 mm” still leaves several questions unanswered: how far apart are the holes, what sits behind each one, and where will the cable enter?

What sizes do push button enclosures come in?
Keep two sets of dimensions separate: the operator mounting format and the box dimensions. A 22 mm or 30 mm description refers to the operator format, not the height or width of the enclosure. Hammond’s 1435 range, for example, has versions with 22.5 mm and 30.5 mm openings.
Here are four catalog examples from its 22.5 mm range:
| Model | Operator holes | Catalog H × W × D, inches | Approximate H × W × D, mm |
|---|---|---|---|
| 1435MA | 1 | 3.50 × 3.25 × 2.75 | 89 × 83 × 70 |
| 1435MB | 2 | 5.75 × 3.25 × 2.75 | 146 × 83 × 70 |
| 1435MC | 3 | 8.00 × 3.25 × 2.75 | 203 × 83 × 70 |
| 1435MH | 6 | 9.50 × 6.25 × 3.00 | 241 × 159 × 76 |
Metric values are converted and rounded to the nearest millimeter. These are examples from one steel enclosure range, not universal sizes or usable internal dimensions.

When comparing features, check how the cover is held during wiring, how the box mounts to the machine, and whether cable entries are already provided. Record those details alongside the dimensions; they affect how you assemble and service the controls.
Start with complete operator part numbers
List every push button, indicator, selector switch and emergency-stop device. Include the mounting hardware and everything attached behind the panel. For a modular operator, the front head alone will not tell you how much room the assembly needs.
Your list should identify:
- The operator model, head shape and any legend plate or guard.
- The mounting adapter, retaining hardware and permitted panel thickness.
- The selected contact blocks and lighting module, where fitted.
- The terminal or connector version and the direction in which its wires leave.

Terminal choice deserves a separate check. APEM’s panel-mount switch guide includes solder-lug, quick-connect and other terminal options across its switch families. Use the drawing for the version you will actually buy, with its mating connector or termination included.
Lay out the heads, holes and rear components together
Begin with the front view. Draw the outline of each button head, selector handle and identification plate around its hole center. Check the handle throughout its travel, and leave the operator room to press or turn the control without hitting its neighbor.
Then look behind the cover. Add the bodies, mounting nuts, contact blocks and connectors to the same layout. Two circular cutouts can sit neatly beside one another while the rear assemblies collide. A cover screw or molded corner boss also occupies space that a front-view drawing can miss.

Use the component’s mounting drawing for the cutout diameter, tolerance and any locating notch. Check panel thickness against its clamping range, including any overlay that changes the mounting thickness. A nominal product description is not a machining drawing.

How far apart should the holes be?
Use the spacing requirements for your exact actuator and accessories. In its 22 mm push button technical data, Rockwell Automation specifically warns that 30 mm hole spacing does not work with certain knob-lever configurations.
For your drawing, confirm the front operating space, the rear component clearance and access for the retaining tool. If one needs a wider pitch, revise the layout before selecting a pre-drilled cover.

Check usable depth with the wiring attached
Measure from the inside mounting face of the cover to the nearest obstruction behind the operator. That obstruction might be the box floor, a mounting rail, a terminal strip or cable-entry hardware. The catalog’s external depth does not give you this measurement.

Place the complete rear assembly in the section view, including its connector. Next, draw where the wire goes after leaving the terminal. A connector pointing toward the floor needs space in that direction; a side-facing connection needs room beside the operator. Apply the cable manufacturer’s bend requirements to the actual cable.
Also check the actions needed during assembly. Can a screwdriver approach the terminal? Can you release a contact block or unplug a connector? A part can fit inside a box while leaving no practical way to service it.

A compact operator can sometimes resolve the depth problem. In EAO’s published CereTom case study, the selected Series 84 emergency stop had a maximum back-of-panel depth of 18 mm. That dimension belongs to the device described in that case. For your assembly, compare the current drawings of suitable operators before committing to a deeper enclosure.
Put the cable entry on the layout now
Draw the complete gland or conduit fitting, including its internal locknut. Then check it against the nearest operator body, fixing point and wire route. A circle on the sidewall shows the opening; it does not show the fitting projecting into the box.
Mark the approach direction of the incoming cable as well. If the box mounts against a machine frame, check that the frame leaves room for the fitting, cable bend and installation tool.

Where devices mount on a removable or hinged cover, show what happens to the connected wires when it opens. Follow the harness through that movement: it must avoid the gasket and screw locations, and allow the cover to open without pulling on terminals. Check this with the intended cable and routing, not an empty box.

Choose standard holes when they fit the complete assembly
Keep a standard enclosure if its hole pattern, usable depth and entry positions work. Ask for custom machining when the body already fits and only the openings need to change. Consider a different body when the depth, mounting arrangement or available face area remains wrong.
| Route | Use it when | Confirm before ordering |
|---|---|---|
| Standard pre-drilled enclosure | The supplied pattern matches the complete operator layout | Exact hole pattern, device compatibility, rear clearance and entry options |
| Standard enclosure with custom openings | The body fits, but the required holes, spacing or entry locations differ | Dimensioned cutouts, machinable areas, orientation and approved drawing revision |
| Custom enclosure body | Available bodies cannot accommodate the assembly or machine mounting | Body geometry, cover construction, mounting details and the full interface drawing |

For a metal cover, check openings close to a formed edge with the fabricator. Protocase’s guidance on cutouts near bends explains how bending can stretch or flare a nearby opening. The necessary distance depends on material, thickness and tooling. Moving a hole toward the edge to gain button spacing can therefore create a manufacturing problem.
If the body needs to change, use a custom electrical enclosure brief that shows the mounting and internal arrangement as well as the front face.
What should you send for a quotation?
For a standard box, send the enclosure part number and operator list, then confirm the complete fit. For custom openings, add a dimensioned drawing that identifies the view, units and revision. Label the front view explicitly so an asymmetric pattern cannot be mistaken for a rear view.
| Information to send | Details that make the request usable |
|---|---|
| Supply scope | Empty enclosure, machined enclosure, or an assembly with separately defined responsibilities |
| Operator list | Exact models, quantities, accessories and mounting drawings |
| Space and mounting limits | Available H × W × D, mounting points and space around the installed box |
| Layout | Front view, rear component arrangement and a section through the deepest assembly |
| Custom cutouts | Hole sizes, locating features, center positions from a stated datum, tolerances, units and drawing revision |
| Cable entries | Entry side, fitting model or thread, cable diameter and intended routing |
| Enclosure requirements | Material, finish, installation environment and required protection rating for the finished configuration |
| Order requirements | Quantity, sample or first-article requirements, and requested delivery date |
Agree on the drawing format the supplier can use. A CAD file can define geometry, while a dimensioned PDF records the tolerances and notes needed for approval. Make clear which revision controls manufacturing.

Prove a new layout before releasing the batch
For a crowded or unfamiliar assembly, check a sample with the selected hardware fitted. Install the operators and cable-entry fittings, connect a representative harness, then check cover closure and service access. Record any changes on the drawing before approving production.

In Tri-Tech 3D’s APEM case study, APEM used a printed alignment jig to drill pushbutton holes into a molded part for a customer’s prototype. The case describes modifying the molding tool if the design proceeded to production.
For your project, agree how the hole positions and assembled fit will be checked before you commit to the batch. A finished sample should let the reviewer reach the terminals and remove the cover, not merely confirm that the buttons pass through the holes.
FAQ
Can I mix operators from different manufacturers?
Check each device against the enclosure drawing. Matching nominal hole sizes does not establish compatibility: cutout details, panel thickness, spacing and rear dimensions still need to match. Keep the manufacturer’s specified mounting and accessory combinations together unless an alternative is approved.
Should I add spare holes for future controls?
Only where you have also reserved rear space and a wiring route. Identify the future device size where possible and specify suitable blanking plugs for unused openings. Include those plugs in the finished enclosure’s protection requirements.
Can I send a sketch instead of a finished CAD drawing?
A marked-up sketch can start the quotation discussion. Include known dimensions and label anything still undecided. Before machining, agree on a dimensioned approval drawing with the supplier so hole positions, tolerances and orientation are fixed.
Send the layout with your enclosure request
Send FN Enclosure your operator list, mounting drawings, target dimensions and cable-entry positions. If a dimension or component is still undecided, mark it on the sketch so it stays visible during review.